The works comprised of construction of a secant pile wall to the site perimeter, excavation, assessment and categorization into relevant classifications and appropriate disposal off site.
Key Features
- Installation of 590 no. 20m long 1200mm CFA piles
- Installation of 355 restraining anchors
- Installation of 5 no. deep de-watering wells and installation of on-site treatment facilities
- Temporary works to maintain LUAS overhead lines
- Classification, excavation and disposal off site of 315,000m3 of material